Model No: DS-812N
Model: DS-812N
Range: 360-780nm
Function: color detection
Measurement Stability: ΔE*ab≤0.015
Caliber: Standard configuration: 10mm glass colorimetric dish, 50mm glass colorimetric dish (optional 33mm and 100mm glass colorimetric dishes)
Support APP: No
Application Areas: Suitable for measuring easily solidified samples such as fat and wax, it can be heated up to 90 ℃ and maintained at that temperature, allowing the sample to be tested in a liquid state
Ukuran: 56.5*42.0*31.5cm
Weight: 8.55kg
Mendukung Perangkat Lunak PC: Mendukung
Menjual unit: | Piece/Pieces |
Tipe paket: | Hubungi tenaga penjualan untuk mengonfirmasi |
The file is encrypted. Please fill in the following information to continue accessing it
Dengan desain optik yang lebih canggih dan kontrol yang tepat dari arah transmisi cahaya, permintaan cairan minimum dikurangi menjadi 1ml, 34% lebih rendah dari generasi sebelumnya, menghemat sampel pelanggan yang mahal. Peralasan spektrofotometer yang kompatibel, tidak diperlukan pembelian tambahan atau peralatan makan khusus.
Product model | DS-812N |
Measurement condition | d/0(,0)(:CIE No.15,ISO 7724/1,ASTM E1164,DIN 5033 Teil7,JIS Z8722 Condition c,GB/T 3555,ASTM D156,GB/T 6540,ASTM D1500,ASTM D1209,ASTM D5386,ASTM D6045,ASTM D6166,ASTM D1502) |
Stand-alone operation | Support |
Integrating sphere | Φ40mm,Avian-D Fully diffuse surface coating |
Lighting source | CLEDs(Full band balanced Led light source) |
Inductor | Dual optical sensor array sensor |
Wavelength range | 360-780nm |
Wavelength interval | 10nm |
Half-band width | 5nm |
Measuring range | 0~200% |
Resolution | 0.0001 |
Observer Angle | 2°/10° |
Observation light source | A,B,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30,U35,DLF,NBF,TL83,TL84,ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V4 |
Display | Pharmacopoeia color number, transmission map/data, sample chromaticity value, color difference value/map, pass/fail result, color deviation, color simulation, historical data color simulation, manual input of standard sample, test report |
Measuring time | ≤1.5s |
Measuring optical path | Standard: 10mm glass cuvette, 50mm glass cuvette (optional 33mm and 100mm glass cuvette) |
Color space | CIE Lab,LCh,CIE Luv,XYZ,Yxy,Transmissivity, Hunter Lab Munsell,MI,CMYK |
Color difference formula | ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*02 |
Other indicators | Pharmacopoeia (Chinese Pharmacopoeia, European Pharmacopoeia, American Pharmacopoeia),WI(ASTM E313-20,ASTM E313-73,CIE,ISO2470/R457,Hunter,Taube Berger Stensby),YI(ASTM D1925,ASTM E313-20,ASTM E313-73),Tint(ASTM E313-20),Allochromic index Milm,APHA,Hazen,Pt-Co(Platinum-cobalt index),Gardner(Gardner index),Iron cobalt index,Saybolt(Seibert index),ASTM Color,EBC(Beer color),ICUMSA Color(Sugar chroma) |
Repeatability | Transmittance: standard deviation ≤0.08% Colorimetric value: ΔE*ab≤0.015 standard deviation, maximum ≤0.04 |
Inter instrument agreement | ΔE*ab < 0.25 |
Heating function | / |
Heating temperature range | / |
Audit trail | Yes (as required by FDA and CFDA) |
Kemasan: Hubungi tenaga penjualan untuk mengonfirmasi
Dukungan tentang: Contact salesperson to confirm
Kode HS: 9027300090
Pelabuhan: C,o,n